First, the use of
This product is used in the coal mine with rated voltage 1KV and the following fixed laying cable, applicable to underground coal mine power transmission.
Two, the use of conditions
Line core to allow the operating temperature of 65 degrees Celsius, cable laying temperature of not less than 0 degrees Celsius, the cable allows the minimum bending radius
15(D+d)±5%。
Model description:
Polyvinyl chloride sheathed mining power cable in mine power transmission lines, but unable to bear external mechanical force MVV22 coal mine with PVC insulation steel tape armoured PVC sheathed power cable for mine in power transmission line insulation model name MVV PVC, can bear certain mechanical external force is MVV32 mine PVC insulated fine steel wire armoured and PVC sheathed power cables in the mine power transmission lines, can bear certain tension MV42 PVC insulated thick steel wire armoured and PVC sheathed mining power cable in mine power transmission lines, can bear larger pulling force |
technical requirement:
Nominal cross section of conductor(mm2) | Rated voltage(KV) | ||
0.6/1 | 1.8/3 | 3.6/6 | |
Insulation Thickness(mm) | |||
1.5 | 0.8 | - | - |
2.5 | 0.8 | - | - |
4 | 1.0 | - | - |
6 | 1.0 | - | - |
10 | 1.0 | 2.2 | 3.4 |
16 | 1.0 | 2.2 | 3.4 |
25 | 1.2 | 2.2 | 3.4 |
35 | 1.2 | 2.2 | 3.4 |
50 | 1.4 | 2.2 | 3.4 |
70 | 1.4 | 2.2 | 3.4 |
95 | 1.6 | 2.2 | 3.4 |
120 | 1.6 | 2.2 | 3.4 |
Rated voltage 1KV and copper core fixed laying crosslinked polyethylene insulated coal mine used to cross linked power cable coal mine safety certificate.
MYJV cable, MYJV22 cable, MYJV32 mine cable products used in coal mine underground rated voltage 0.6 / 1KV and the following transmission and distribution lines.
First, the use of
This product is used in the coal mine with rated voltage 1KV and the following fixed laying cable, applicable to underground coal mine power transmission.
Two, the use of conditions
Line core long-term allowable operating temperature of 90 degrees Celsius, cable laying temperature is not less than 0 degrees, cable allows the minimum bending radius of 15 (D+d) + 5%.
model | Name |
MYJV | Cross linked polyethylene insulated and PVC sheathed power cable for coal mine |
MYJV22 | XLPE insulated PVC sheathed power cable for mine |
MYJV32 | Power cable with XLPE insulated fine steel wire armoured PVC sheathed coal mine |
MYJV42 | XLPE insulated steel wire armoured PVC sheathed power cable for mine |