Security code: | huininggroupnmpGY1172Bpfu2H340 |
---|---|
browse: | |
add time: | 2016-01-16 14:06:44 |
recommendation: | ![]() ![]() ![]() ![]() ![]() |
Inductance type liquid level transmitter system can be of various physical parameters change is converted to a standard current signal, remote to control room, for the secondary instrument or computer centralized display, alarm or automatic control. The good structure and installation, can be applied to high temperature, high pressure, strong corrosion, easy to crystallize, anti blocking, anti cold junction and solid powder and granular materials under special conditions of liquid level and continuous measurement of material position or level, widely used in various industrial processes for measurement and control.
characteristic
The structure is simple: there is no movable or elastic element, so it is very easy to stay, and the amount of maintenance is very small.
Installation is convenient: the built-in type structure, in particular, shows this feature, without any special tools.
Adjustment convenient: zero, range two potentiometer can be in the effective range of liquid level detection of zero migration or range of change, the two adjustment does not affect each other.
Suitable for high temperature and high pressure, strong corrosion and other media liquid level measurement.
Technical index
Pressure range: negative pressure, atmospheric pressure, high pressure (32MPa)
Operating temperature: -50 ~ 240
Ambient temperature: -20 ~ 75
Applicable medium: acid, alkali, salt or any medium with no corrosion to PTFE
Output signal: 4-20mA, second tier system
Power supply: load resistance 0-750 DC24V
Fixed way: screw mounting M20 * 1.5, M27 * 2 flange installation DN15, DN25, DN50, DN80.
Field display: analog display 0-100%, digital display, the scene depth
Naming mode
Type spectrum | explain | |||||||||
MY | ||||||||||
Class quality | 01 | Cable type liquid level transmitter | ||||||||
02 | Insert rod type liquid level transmitter | |||||||||
Transmitter type | G | Standard type | ||||||||
D | Explosion proof type (Exd II CT6 1 zone does not contain acetylene) | |||||||||
I | Intrinsically safe (Exd II CT4 1) | |||||||||
Process connection type | T | External thread connecting pipe M20 * 1.5 | ||||||||
F | Flange PN 0.6MPa GP9119.6-88 DN50 | |||||||||
E | Flange PN 0.6MPa GP9119.6-88 DN100 | |||||||||
S | M27 * 2 external screw thread | |||||||||
Y | Special requirements of agreement | |||||||||
Seal requirement | 4 | Corrosion resistance | ||||||||
8 | Anti crystallization | |||||||||
Indicator | M1 | The pointer meter | ||||||||
M2 | Digital display | |||||||||
Precision grade | 02 | 0.5% | ||||||||
05 | 1% | |||||||||
07 | 1.5% | |||||||||
-□ | Line length(mm) | |||||||||
-□ | Liquid level measuring range(mm) |