3351GP type pressure transmitter for measuring liquid, gas or steam liquid level, density and pressure, and then change into 4 ~ 20mADC signal output. 3351GP intelligent pressure transmitter can communicate with the HART hand operator, through which it is set, monitoring or with the host computer to form a field monitoring system. 3351GP field adjustment type intelligent pressure transmitter is the company according to the requirements of the field of development and development of new products, can be separated from the hands of the operator, through the button to achieve the scene zero adjustment, configuration and other operations.
1 performance specifications
Zero reference calibration range, reference conditions, silicone oil filling, 316L stainless steel isolation diaphragm.
1.1. reference accuracy
1.1.1. digital, intelligent: + 0.1% calibration range
1.1.2. simulation, linear: + 0.2% calibration range
1.2. stability
1.2.1. numbers, intelligence: 6 months, plus or minus 0.1%URL
1.2.2. simulation, linear: 6 months, plus or minus 0.2%URL
1.3. ambient temperature effect
1.3.1. digital, intelligent:
Zero error: + 0.2%URL/56
Overall error: + (0.2%URL+0.18% calibration range) /56
1.3.2. simulation, linear
Zero error: + 0.5%URL/56
Overall error: + (0.5%URL+0.5% calibration range) /56
1.4. vibration effect
In arbitrary axial direction, the effect of 200Hz vibration is + - 0.05%URL/g
1.5. power effect
Output range of less than + 0.005%.
1.6. load effect:
There is no load effect unless the supply voltage is changed.
1.7. electromagnetic interference / radio frequency interference (EMI/RFI)
From 20 to 1000MHz, up to 30V/M field, the output drift less than 0.1% range.
1.8. installation location effect
Zero drift is at least 0.25kPa. All zero drift can be corrected; no effect on the measuring range.
2 functional specifications
2.1. measurement range: 0-0.125-41370KPa
2.2. zero and range
2.2.1. digital, intelligent
Can use the machine range and zero button adjustment, or use HART hand operator remote adjustment
2.2.2. simulation, linear
Adjustable range and zero point
Zero positive and negative transfer of 2.3.
Zero negative migration, the lower limit of the range must be greater than or equal to the URL; zero is migration, the upper range must be less than or equal to the +URL. The calibration range must be greater than or equal to the minimum range.
2.4. output
Digital, intelligent:
4 ~ 20mADC, the user can choose linear or square root output. The digital process variable is superimposed on the 4 ~ 20mA signal, which can be used by the host computer using HART protocol.
Simulation, linear:
4 ~ 20mADC, and the process pressure into a linear.