In the thermocouple internal use card dead even wire, completely prevent leakage or leakage. It is suitable for the production of high wear-resistant solid particles or fluid in the field. It is an indispensable temperature measuring device for oil refinery.
application
Wear resistance leakage thermocouple summary: wear resistance leakage thermocouple and wear-resistant thermocouple is a kind of product, the only difference is that the internal device is not the same, the card sleeve screw stuck, can thoroughly prevent the occurrence of oil spills or leak phenomenon, wear resistance leakage thermocouple suitable for fluidized bed, the fluidized furnace, cement kiln, oil refineries and other existing containing high wear resistant particles or fluid ideal temperature measuring instrument.
Main technical parameters
Electrical outlet: M20X1.5NPT1/2
Wear head hardness: HRC62-65
Protection level: IP65
Explosion proof grade: D, BT4, D, CT5
Nominal pressure: 2.5MPa
Specifications and models
Model | Graduation | measuring range | Thermal response time | Protective tube material | Specifications LX1 |
WRN-430M WRN2-430M | K | 0-800 | < 180S | 1Cr18Ni9Ti | 450X300 500X350 550X400 600X450 650X500 750X600 950X800 1150X1000 |
WRE-430M WRE2-430M | E | 0-600 | |||
WRN-440M WRN2-440M | K | 0-800 | |||
WRE-440M WRE2-440M | E | 0-600 |