There are no significant temperature gradients in the production site, and multiple measurements at the same time to measure multiple locations or single locations. Multipoint thermocouple is widely used in large chemical fertilizer synthesis tower, storage tank and so on.
Main technical parameters
Electrical outlet: M27X2, NPT3/4
Thermal response time: ≤ 8S
Wire diameter:Φ3
Protection level: IP65
Model and specifications
model | Index number | measuring range℃ | Temperature measuring point | Protective tube material |
WRN-230D | K | 0-1000 | 2-12 | GH3030 |
0-827 | 1Ci18Ni9Ni | |||
WRE-230D | E | 0-1122 | 1Ci18Ni9Ni | |
WRN-430D | K | 0-1000 | GH3030 | |
0-827 | 1Ci18Ni9Ni | |||
WRE-430D | E | 0-1122 | Ci18Ni9Ni |
1, thermocouple I order according to the agreement;
2, multi-point thermocouple protection tube and the rest of the material according to the agreement order;
3, multi-point thermocouple protection tube users should bring their own
Installation fixed form
Fixed screw thread
Temperature measuring point | M | D | H | h | SW | d |
2—6 | M27x2 | ¢40 | 28 | 5 | 32 | ¢20 |
7—12 | M33x2 | ¢48 | 33 | 5 | 36 | ¢34 |
Temperature measuring point | D | D1 | D2 | H | do | d |
2—6 | ¢105 | ¢75 | — | 5 | 32 | ¢20 |
7—12 | ¢115 | ¢85 | — | 5 | 36 | ¢34 |