WeChat marketing
Welcome attentionHui Ning groupWeChat public account
1扫描以上二维码2加微信号:HN_GROUP
Welcome to the Hui Ning group !Main products:power cable,Special cable,Computer cable.     phone:0550-7561599
gonggao:

Capacitive vortex flowmeter

Security code: huininggrouprVD7AXTKy0oPhO5153
browse:
add time: 2016-01-16 17:10:18
recommendation:

Buy join the shopping cart

introduction

introduction

打印本文             

A summary of capacitive vortex flowmeter products

LUGB vortex flowmeter is developed by fluid vibration theory of a new flow meter, which is widely used in petroleum, chemical, metallurgy, paper and other industries fluid measurement, the flowmeter without moving parts, high reliability, high precision, long service life, can be in a wide flow Fan Wai in the accurate measurement of liquid instantaneous flow and cumulative flow.

Two, the product characteristics of capacitive vortex flowmeter

1 vortex flow sensor has the advantages of simple structure, no moving parts, convenient installation and maintenance, long service life.

2 vortex flow sensor small pressure loss, wide measurement range.

3. The vortex flow sensor piezoelectric force detection independently installed in the vortex generating body rear, to reduce the impact of the dirt in the medium.

The detecting element 4 of vortex flow sensor is not directly contacted with measured medium flow measurement, particularly suitable for harsh environment.

5 vortex flow sensor field display, also can be remote, but also with the computer networked control system.

Three, the technical parameters of capacitive vortex flowmeter

When the fluid to flow through the set of vortices in a fluid body, in the downstream of the cylinder produced to appear alternately and arranged in neat vortex column (vortex), first on one side of the cylinder, and then in the other side of the column body is produced. This produce first proposed by Carmen (Karman vortex theory, named as the Karman vortex street, and gives the frequency and velocity relationship, where the coefficients are named Strouhal number.

When the nominal diameter: 15~1200mm

This medium: liquid, gas, steam

After the medium temperature of -40~350 DEG C

This connection: flange clamp type, flange type, plug-in www.jshy01.com

When the nominal pressure: 2.5MPa, 4.0MPa

This accuracy level: Level 1, level 1.5, level 2.5

I repeat: less than or equal to 0.3%, 0.5%, 1%

No body material: 1Cr18Ni9Ti

When the load resistance: lt; 750.

After the power supply: 24VDC, 3.6V lithium battery

All output signals: pulse frequency, 4~20mADC, RS485

This velocity range: 0.5~6m/s liquid, gas 5~60m/s

This explosion-proof grade: ia II CT1 - T6 intrinsically safe (and supporting the use of Zener safety grid)

This protection grade: IP

Vortex flowmeter installation

Vortex flowmeter installation requirement for straight pipe is very important. Its detailed requirements are as follows:

Flow meter on the installation point of the upstream and downstream straight pipe section of a certain requirement, otherwise it will affect the accuracy of the measurement.

If the flow meter installation points on the upstream of the tapered pipe, flow meter upstream should be not less than 15D (D diameter) of the straight pipe section, downstream should be not less than 5D of the straight pipe section. If the meter installation point upstream diffuser, upstream of the flowmeter should be not less than 18D (D is the pipe diameter) of the straight pipe section, downstream should be not less than 5D and straight segment if the flow meter is installed upstream 90 degree elbow or downlink joint, upstream of the flowmeter should be not less than 20d of straight pipe section, downstream should be not less than 5D of diameter straight sections. If the flow meter installation point upstream in the same plane with 90 degrees elbow, flow meter upstream should be not less than 25D, such as straight pipe section, downstream should be not less than 5D of the straight pipe section.

Flow control valve or pressure regulating valve as installed in the flowmeter downstream 5D in the distance, if it must be installed in the upstream of the flowmeter, flow upstream should be not less than 25d of straight pipe section, downstream should be not less than 5D of straight segments.

If there is a piston or plunger pump and piston type or roots type blower, compressor, flowmeter upstream should be not less than 25d of straight pipe section, downstream should be not less than 5D the straight segment of the reaches of the flowmeter.

Special note: vortex flowmeter installed upstream of the point is near if equipped with valves, constantly switch valve, the meter service life influence is great, very easy to meter caused permanent damage to. Flowmeter as far as possible to avoid in overhead very long pipeline installation, after such a long time, due to sagging of the flowmeter is likely to cause the flowmeter in the flange seal leakage, if not installed must in flowmeter at 2D upstream and downstream are respectively provided with a fastening device of the pipeline.

sy.jpg


on ano
nextUltrasonic flowmeter


CONTACT

We always believe that the "user first, quality first" purpose and dedication to provide quality services for the majority of users

  • phone:0550-7561599
  • fax:0550-7561496
  • address:Anhui province Tianchang city Tongcheng town Qiaoba road No. 99

ScanningVisitMobile version

Scan two-dimensional code concerned about WeChat

popular keywords:
Anhui HuiNing Electric Instrument Group Co., Ltd.  皖ICP备05001032号-3