gonggao:

Power station thermocouple / thermal resistance

Security code: huininggroupU3Hgt0bicCfvXtP408
browse:
add time: 2016-01-14 17:17:02
recommendation:

Buy join the shopping cart

introduction

introduction

打印本文             

working principle

The electrode of the special thermocouple used in power station is composed of two different conductor materials. When there is temperature difference between the measuring end and the reference end, it will generate the heat potential, the working instrument will show the corresponding temperature value of the thermal electric potential.

Thermal resistance is the use of material in the temperature change, the resistance is also changing with the characteristics of the temperature measurement. When the resistance changes, the instrument will display relevant resistance temperature.

technical parameter

Product implementation standard

IEC584

IEC751

IEC1515

JB/T18622-1997

JB/T8623-1997

GB/T16839-1997

With the continuous development of China's power industry, the need for a variety of temperature measurement of the power station dedicated to replace the imported products. The factory in order to catch up with the international advanced level, and also for the country save foreign exchange, successively from abroad introduced a professional manufacturing technology and equipment, and on the basis of original products, listen to the views of the design institute and power users, the reference to the United States EBASCO specification and redesign of products, increase of new varieties, the whole matching series of varieties, specifications fully meet domestic or imported 30 million, 60 million kilowatts of generating units and other domestic units supporting the needs and its excellent quality to meet the market.

4, measurement range and tolerance

model
Index number
Tolerance level



I
II




Permissible difference
Measuring range°C
Permissible difference
Measuring range°C


WRN
K
±1.5°C
-40~+375
±2.5 °C
-40~+333
±0.004ltl
375~1000
±0.0075 ltl
333~1200


WRM
N
±1.5°C
-40~+375
±2.5°C
-40~+333
±0.004 ltl
375~1000
±0.0075 ltl
333~1200


WRE
E
±1.5°C
-40~+375
±1.5°C
-40~+333
±0.004 ltl
375~800
±0.004 ltl
333~900


WRF
J
±1.5°C
-40~+375
±1.5°C
-40~+333
±0.004 ltl
375~750
±0.004 ltl
333~750


WRC
T
±1.5°C
-40~+125
±1°C
-40~+133
±0.004 ltl
125~350
±0.0075 ltl
133~350


          

  5, room temperature insulation resistance thermal resistance at ambient temperature of 35 - 15°C, relative humidity is less than 80%, the test voltage of 10 - 100V (DC) electrode and the insulation resistance between the outer sleeve >100Ω.m Thermocouple at ambient temperature is 20 + 15°C, relative humidity is not more than 80%, the test voltage is 500 + 50V (DC) electrode and the insulation resistance between the outer sleeve >1000Ω.m

sy.jpg


on aBearing thermocouple / thermal resistance
nextno


CONTACT

We always believe that the "user first, quality first" purpose and dedication to provide quality services for the majority of users

  • phone:0550-7561599
  • fax:0550-7561496
  • address:Anhui province Tianchang city Tongcheng town Qiaoba road No. 99

ScanningVisitMobile version